MS SERIES PV MODULE


SUPERIOR PROJECT RETURNS
» Low Voc enables up to 34 modules per 1000V string; 25A fuse rating allows two strings to be combined in parallel
» Corner junction boxes reduce install labor and eliminate cable tie downs
» Frameless design eliminates need for module grounding
» Better ground coverage ratios and increased energy in partial shading due to embedded bypass diodes
» Higher output due to +5/-0 watts positive binding
RELIABLE PERFORMANCE
» Innovative UltrawireTM creates fault tolerant, low resistance interconnect
» Unique weather protection system provides optimum defense against adverse weather, humidity and mechanical damage
» Rigorous test-to-fail philosophy; thermal tested to 1400 cycles; damp heat tested to 7000 hours for moisture barrier
» Five-year product warranty and 5/10/25 year warranty against power loss
» Dual tempered glass ensures extremely low breakage
SAFETY AND ENVIRONMENT
» Sophisticated and comprehensive quality management system
» Fully equipped UL certified internal test facilities
» Fully automated factory ensures repeatable build quality
» Three month energy payback
| ELECTRICAL PERFORMANCE AT STC* | MS120GG | MS125GG | MS130GG | MS135GG | MS140GG | |
| Nominal Power PMPP | [W] | 120 | 125 | 130 | 135 | 140 |
| Power Output Tolerance PMPP | [W] | +5/-0 | +5/-0 | +5/-0 | +5/-0 | +5/-0 |
| Maximum Power Voltage VMPP | [V] | 19.0 | 19.5 | 20.1 | 20.5 | 21.0 |
| Maximum Power Current IMPP | [A] | 6.29 | 6.41 | 6.48 | 6.58 | 6.67 |
| Open Circuit Voltage VOC | [V] | 24.9 | 25.2 | 25.4 | 25.6 | 25.8 |
| Short Circuit Current ISC | [A] | 7.35 | 7.35 | 7.35 | 7.35 | 7.35 |
| Maximum Series Fuse Rating | [A] | 25 | ||||
| Maximum System Voltage (IEC/UL) | [V] | 1000 / 600 | ||||
*Standard Test Conditions (STC): 1000 W/m2, 25°C cell temperature, AM 1.5 spectrum.
| ELECTRICAL PERFORMANCE AT NOCT** | MS120GG | MS125GG | MS130GG | MS135GG | MS140GG | |
| Nominal Power PMPP | [W] | 84.1 | 87.3 | 90.6 | 93.9 | 97.3 |
| Maximum Power Voltage VMPP | [V] | 16.6 | 17.1 | 17.5 | 18.0 | 18.5 |
| Maximum Power Current IMPP | [A] | 5.05 | 5.11 | 5.17 | 5.21 | 5.26 |
| Open Circuit Voltage VOC | [V] | 21.9 | 22.2 | 22.6 | 23.0 | 23.3 |
| Short Circuit Current ISC | [A] | 5.78 | 5.82 | 5.86 | 5.91 | 5.95 |
**At Nominal Operating Cell Temperature (NOCT): 800 W/m2, 20°C cell temperature, 1 m/s wind speed.
| THERMAL CHARACTERISTICS | ||
| NOCT | [°C] | 49 |
| Temperature Coefficient of PMPP | [%/°C] | -0.45 |
| Temperature Coefficient of VMPP | [%/°C] | -0.36 |
| Temperature Coefficient of ISC | [%/°C] | -0.003 |
| PHYSICAL AND MECHANICAL SPECIFICATIONS | |
| Length | 1611 mm (63.4 in) |
| Width | 665 mm (26.2 in) |
| Depth | 7.5mm (0.3 in); 28 mm (1.1 in) including junction box |
| Weight | 18 kg (39.7 lbs) |
| Junction Box / Output Terminal Type |
2 corner connection boxes/ MC4 type |
| Cell Type | Copper Indium Gallium Diselenide (CIGS) |
| Maximum Load | Tested snow load: 5400 N/m2 |
| Warranty Term** | 5/10/25 year power output, 5 year workmanship*** |
| Certifications | IEC 61646, IEC 61730 (Application Class A), UL1703 (Fireclass A), CEC |
***Please see full warranty for details.
MiaSolé and the MiaSolé logo are registered trademarks.
© October 2011 MiaSolé. All rights reserved.
Specifications included in this datasheet are subject to change without notice.
MiaSolé Approved for Public Release.